Your Professional Sewage Lifting Pumping Station Manufacturer!
Hangzhou Ruifeng Environmental Protection Technology Co., Ltd. is a diversified high-tech enterprise integrating research and development, manufacturing, sales and service. The company's main sewage pump, integrated prefabricated pump station, integrated sewage treatment equipment, catering oil and water separation equipment and integrated sewage upgrading equipment.
Why Choose Us
Quality Control
We strictly follow the ISO 9001 series of standards for quality control to ensure that all products undergo comprehensive performance tests before leaving the factory to ensure the reliability of product quality.
Production Capacity
The company has strong production capacity, with more than 100 employees, a plant area of 5,000 square meters, and equipped with various heavy and precision processing equipment to meet diverse production needs.
OEM and ODM Services
For OEM and ODM business, when you put forward specific requirements, our professional team of engineers will quickly provide you with customized solutions. We not only provide a wide range of products, but also provide comprehensive technical support according to your actual needs to ensure that you choose the most suitable products for you.
Patent Certificate
We have obtained Environmental management system certification, quality management system certification, occupational health and safety management system certification, design patent certificate, utility model patent certificate, etc.
-
Large Sewage Lifting Pumping StationPump stations are widely used in public construction projects such as airports, high-speed railways, subways, and large commercial complexes located in sewage pipelinesThe drainage improvement of sewage facilities in underground areasread more
-
Large Horizontal Pump Sewage Lifting Pumping StationThe DPX pump station belongs to an integrated pump station unit, which includes check valves, pressure transmission devices, controllers, and other integrated pump station units that can be directly installed. Suitable for the applicationread more
Custom Sewage Lifting Pumping Station
Custom sewage lifting pumping stations vary by application. Depending on the application, there are numerous options. Some options include:
Pumps
● Specifically designed for sewage and waste water handling applications.
● Duplex or triplex pump configurations sized to meet your pumping requirements.
● Heavy-duty construction and easy-to-service design.
Enclosure
● Provides a superior barrier to caustic or acidic atmospheres.
● Vandal-resistant design for added security.
Controls
● Robust, custom engineered, automatic controls to operate pump function and warning systems.
● Choose from a variety of adjustable pressure controls, overload reset buttons and circuit breakers for station accessories.
● Clearly marked field connections for fast and efficient electrical hook-up.
Sewage Lifting Pumping Station Technical Parameters
|
Pump speed |
2900r/min |
|
Rated flow |
4.1L/s |
|
Maximum flow |
8L/s |
|
Rated head |
15m |
|
Maximum head |
17m |
|
Maximum flow capacity |
50mm |
|
Impeller type |
Swirl type |
|
Main shaft seal |
SIC/SIC |
Sewage Lifting Pumping Station Electrical Data
|
Input power P1 |
1.9kW |
|
Output power P2 |
1.5kW |
|
Power frequency |
50Hz |
|
Rated voltage |
3x380 |
|
Rated current |
3A |
|
Voltage difference |
(+6/-10%) |
|
Maximum number of starts per hour |
60 |
|
Number of motor poles |
2 |
|
Starting method |
SD |
|
Protection level |
IP68 |
|
Insulation level |
F |
|
Built-in protector |
Thermal switch |
|
Cable length |
5m |
|
Motor immersion depth |
6m |
Large Sewage Lifting Pumping Station
Pump stations are widely used in public construction projects such as airports, high-speed railways, subways, and large commercial complexes located in sewage pipelines The drainage improvement of sewage facilities in underground areas below the horizontal line.
Large Horizontal Pump Sewage Lifting Pumping Station
The DPX pump station belongs to an integrated pump station unit, which includes check valves, pressure transmission devices, controllers, and other integrated pump station units that can be directly installed. Suitable for the application of sewage lifting systems in new construction and renovation of old houses.
Our Company Has More Products to Offer, Please Browse the Product Categories on the Website, If You Have Any Needs, Please Contact Us.

● Municipal pumping stations from small to large
● Highway rest areas
● Courthouses and jails
● Casinos, hotels and resorts
● Hospitals and nursing homes
● Shopping plazas
● Colleges and universities
Installation Best Practices for Sewage Lifting Pumping Stations
Before installing a sewage lifting pumping station, it is crucial to ensure that the site is adequately prepared. This includes carrying out thorough ground assessments and addressing any potential obstacles, such as underground utilities and foundations. Additionally, proper excavation and shoring techniques should be employed to create a safe working environment and provide a stable base for the pumping station.
The placement of the pump station must be carefully carried out to ensure a secure and stable fit. Adequate anchoring and support structures should be used to prevent movement during operation. When installing pipework, ensure that pipe runs are as straight and short as possible, reducing friction losses and maintaining optimal flow rates. Proper sealing and connection of joints are essential in preventing leaks and maintaining system reliability.
Following successful installation, system commissioning must be conducted to ensure that all aspects of the pumping station are functioning as intended. This process includes testing and adjusting pump performance, verifying control functionality, and ensuring that all safety features are operational. Thorough commissioning helps to identify any potential issues early on, reducing the likelihood of future problems and ensuring smooth operation.
Precautions for Operation of Sewage Lifting Pumping Station
Dry running of the sewage lifting pumping stations should be avoided.
Sewage lifting pumping stations if installed with negative suction should be primed before starting.
Sewage lifting pumping stations should be operated only within the recommended range of the head discharge characteristics of the sewage lifting pumping station.
• If sewage lifting pumping station is operated at a point away from duty point, the sewage lifting pumping station efficiency normally reduces.
• Operation near the shut-off point should be avoided, as it causes substantial recirculation within the sewage lifting pumping station, resulting in overheating of sewage in the casing and consequently, overheating of the sewage lifting pumping station.
As far as possible positive suction is to be provided to avoid priming during design itself.
Voltage during operation of the sewage lifting pumping station-motor set should be within ±10% of the rated voltage. Similarly, current should be below the rated current shown on the name plate of the motor.
When parallel sewage lifting pumping stations are to be operated, the sewage lifting pumping stations should be started and stopped with a time lag between two sewage lifting pumping stations to restrict change of flow velocity to minimum and to restrict the dip in voltage in the incoming feeder and should be adequate to allow the sewage lifting pumping station head to stabilise.
When the sewage lifting pumping stations are to be operated in series, they should be started and stopped sequentially, but with minimum time lag. Any sewage lifting pumping station next in sequence should be started immediately after the delivery valve of the previous sewage lifting pumping station is even partly opened. Due care should be taken to keep open the air vent of the sewage lifting pumping station next in sequence, before starting that sewage lifting pumping station.
The stuffing box should allow a drip of leakage to ensure that no air passes into the sewage lifting pumping station and that the packing gets adequate wetness for cooling and lubrication.
If any undue vibration or noise is noticed, the sewage lifting pumping station should be stopped immediately and the cause for vibration or noise should be checked and rectified.
The number of starts per hour shall not exceed four. Frequent starting and stopping should be avoided as each start causes overloading of motor, starter, contactor and contacts. Although overloading lasts only for a few seconds, it reduces the life of the equipment.
Product Warranty
According to the terms of the contract, the equipment provided enjoys a two-year warranty service from the date of successful installation and commissioning, of which the electrical part has a warranty period of 18 months.
Our Certificate



FAQ
We're well-known as one of the leading sewage lifting pumping station suppliers in China. If you're going to wholesale high quality sewage lifting pumping station, welcome to get quotation from our factory. For price consultation, contact us.
sewage lifting installation, sewage elevation installation equipment, sewage pump works equipment-
Wastewater Lifting UnitWastewater Lifter offers extremely low inlet, multiple sizes to meet the wastewater lifting of family homes withoutread more
-
Toilet Sewage LifterToilet Sewage Lifter is a small wastewater lifter for wastewater lifting needs with a toilet, with reserved connectionsread more
-
External Single Pump Sewage Lifting UnitThe external single pump sewage lifting device series pump station is a compact, heavy-duty, high-reliability, fullyread more
-
External Double Pump Large Sewage Lifting DeviceThe DPX series pump station is a compact, heavy-duty, highly reliable, fully enclosed sewage lifting pump station unit,read more
-
Built-in Pump Sewage Lifting DeviceBuilt-in pump sewage lifting device can be used for villa basement single bathroom drainage as well as office orread more
-
Large Sewage Lifting Pumping StationPump stations are widely used in public construction projects such as airports, high-speed railways, subways, and largeread more
